Home | S-100 Boards | History | New Boards | Software | Boards For Sale |
Forum | Other Web Sites | Quiz | Index |
The controller could work with up to 6 separate drives and utilized DMA memory access for fast data transfers. The software supplied was fairly complex and set to work with their Cromix Multi-user system. However they did also supply a stripped down CDOS (~CPM) version as well. If you are going to use this board start with their HDIAG diagnostic program. BTW, a fast 4MHz CPU was required. A 2 MHz Z80 could not keep up with the data. The board had interrupt capability but was not used by their software. There was elaborate circuitry to handle S-100 systems that had multiple DMA controllers on the bus. Again some 15 IO ports were eaten up to run the board. The default port with their software was E0H to EFH.
Other Cromemco S-100 Boards
This page was last modified on 01/08/2011